Bosch Solution Link 2.2.8 Release Notes


  • Support for Bosch Solution 6000-IP Panels
The Bosch Solution 6000-IP panel is now available for installations which do not require analog phone connectivity (PSTN). Remote connectivity is still available using direct IP addressing or via MyAlarm. For local programming direct connectivity is still available via the CM910B USB lead.
  • New Macro Scenes Countdown Command
New Macro Scene Countdown command (C) is now available. This parameter is useful when a period of delay needs to be inserted between commands. For example, entering the scene: A1&C60&A2, will arm Area 1, then wait 60 seconds, then Arm area 2. Countdown range is from 0 to 65535 seconds (C0 to C65535) with the highest value corresponding to 18 hours, 12 minutes and 15 seconds. This command is available for Bosch Solution 6000 (from revision 2.53.16) and Bosch Solution 6000-IP panels.
  • Fix to Zone Expansion Numbering
Previously, expansion device markers in Panel Zone Summary view was set at the incorrect offset. This has now been corrected.
  • Fix to Device GSM Options Import
Certain GSM options were not being loaded when importing a customer. This has now been corrected.
  • Fix to Unresponsive Keypad Simulator
The keypad simulator would occasionally become unresponsive on slow networks, this has now been corrected.
  • New Faster Upload/Download for Bosch Solution 6000-IP Panels
The Bosch Solution 6000-IP panel uses a global checksum to determine if an upload or download is necessary. Uploads and/or downloads are skipped if deemed redundant.
  • New Migration from Bosch Solution 6000 to 6000-IP Panels
A new option is available to migrate a Bosch Solution 6000 to a Solution 6000-IP panel. To perform a migration, in Customer Summary view, right-mouse click over the desired panel and select Migrate from the popup menu.
  • New RAS Security Default PIN Check
When saving panel data, the RAS security PIN is checked for default value of 12345678. A warning is displayed if this PIN is still at its default setting.
Please ensure that the RAS PIN is always changed from default so that only authorised installers are allowed to access the panel remotely via Bosch Solutionlink.
  • Fix to Permaconn™ Connections
Connection via modem now works in conjunction with Permaconn™ Virtual Modems.
* Windows is a trademark of Microsoft Corporation.
* Permaconn is a trademark of RDCCO Pty Ltd.
12:00 PM - 1 OCT 2021